11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V


Light Equipment & Tools. Electrical & Test Equipment. Healthcare, Lab & Life Science. Other Business & Industrial. Art & Craft Supplies. 11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V. This product incorporates a wide range of refrigeration technology, simple operation and precise temperature control. Anti-interference ability, suitable for all kinds of refrigeration, heating equipment automatic intelligent control system. Sensors with a special precision machining package with moisture barrier, stable and reliable performance. Specifications: Operating voltage: AC220V 50HZ / 60HZ Output load: 220V AC Power: 11 KW Working environment: -10 50 , RH90% Control range: -45 80 Resolution: 1 Accuracy: ± 1 Input signal: one road measure temperature sensor, 20K X 1.5m Machine size: 445 x 345 x 102mm/17.52 x 13.58 x 4.02inch Outer hole size: 42mm/1.65inch Inner hole size: 38mm/1.5inch Net Weight: 7.36kg Control system automatically heat-up procedure 1. Preparation stage Once reconnected to power or if the water temperature is 1 below the user setting temperature at least 10 minutes after entering the waiting stage, the heater enters the preparation stage. PUMP WORKING’indicator lights. If hint message” does not appear on the panel within 2 minutes, and the water temperature is 1 below the user setting temperature after 2 minutes, the heater enters next stage pre-heat stage. Pre-heat stage In this stage, heater heats up for 10 seconds and waits for 90 seconds. Heating’ indicator lights for 10 seconds. If hint message” does not appear on the panel and the water temperature is 1 below the user setting temperature, heater enters next stage heat-up stage. Heat-up stage In this stage, all heating elements turn on, and heating indicator turns on as well. If hint message” does not appear, heater will heat up to 1 above the user setting temperature, then heating indicator blinks for 2 minutes. After that , circulation pump turns off for models with circulation pump control. Heater enters next stage waiting stage. Waiting stage Waiting stage lasts for at least 10 minutes. 10 minutes later, if the water temperature is 1 below the user setting temperature, the heater jumps to preparation stage, otherwise, it remains in the waiting stage. The automatically heat-up process is non-stopping and will continue to circulating through all stages until the control system or heater is power off. You could ask for models with separated circulation pump control function. Unique control system 1. The flow-temperature sensor is always under the control of software, accurately monitoring the temperature status of the whole system, and then adjust the settings to maintain the water temperature and protect the heater from unexpected situations. No mechanical sensors, avoid any mechanical failure to affect the function of the heater. Avoid affection of ion accumulation to mechanical sensors. Greatly reduce unnecessary circulation cycles, prolong the life of circulation pumps and save more energy. Before using the installation requirements: 1. The power supply voltage and the voltage marked on the machine to be consistent, deviation of supply voltage and the rated voltage is not more than ± 10%. The sensor should maintain an appropriate distance from the power line, avoid contact or close. The strict distinction between sensors, power lines and the output relay interface. A vailable in single phase and three phase configurations. The heater is suitable for indoor or outdoor installation. See figure 1 for piping connections and figures 2A and 2B for electrical connections. Leave minimum clearance of 9 inches on the left, 12 inches both above and to the front and 6 inches on the back for service entrances and access. Note: This can only be used in pools around 8-10 cubic meters. 1 x 11KW 220V Swimming Pool Electric Water Heater. SPECIFICATIONS: Power 11 KW/50A Voltage 220V (Transformer required) Phase 1/3 Frequency 50Hz Size 19″ x 4″ x 14 Net Weight 14.3 Lbs DESCRIPTION Intelligent temperature control, stable performance, safe and reliable Automatic constant temperature, can be adjusted according to the required water temperature. The maximum set temperature is about 55. Safe and reliable, machine matched pressure switch. When the pressure is lower than the set value, the power is automatically turned off. Do not heat sea water or salt water. The thermostat must work with a matched capacity water pump. If the pump and the thermostat do not match, the flow rate is too small, the heating tube is dry and easily damaged 5.5KW-15KW heaters must work with a pump, which the water flow is 195-530 ft³/per hour. 18KW heaters must work with a pump, which the water flow is 635 ft³/per hour 11KW thermostat is suitable for 389 ft³ pool Thermostat is recommended to use with circulating water pump Operation sequence: turn on the water pump first, then turn on the thermostat. Shutdown: Turn off the thermostat first, wait for a while (depending on the power of the thermostat, 10 seconds to 1 minute) and then turn off the pump. Reliable leakage protection equipment must be installed and must be installed and commissioned by the ruling electrician. Monthly maintenance and inspection. The auxiliary heating effect of the thermostat is better. Direct heating requires the use of a more powerful machine. MANUAL RESET TEMPERATURE CONTROL SWITCH Prevent water from burning dry and overheat protection Automatic shutdown with water shortage. The machine will not work if it does not start the pump, it can effectively prevent water shortage and nonstandard operation from causing damage to the machine. Temperature limit switch It has automatic shutdown when the temperature reaches the temperature, and can automatically start the heating function after the temperature is lowered, which can effectively prevent the damage caused by excessive machine temperature. Fuse protection When the current is too large, the fuse switch will be disconnected immediately and the power will be cut off. Power protection switch Use AC contactor as the start switch. No matter what kind of accident occurs, you can quickly disconnect the power supply and protect the safety of the machine and people. Intelligent self-diagnose function The control system keeps on monitoring the running status of every parts of the heater, and quickly reacts and displays corresponding hint message for any incident, so as to avoid any damage or malfunction happens. If any fault happens, the heater is stopped immediately, and corresponding hint message will display on the panel for user or technician to decide where the fault is. The safety of customer is the top priority PACKAGE INCLUDED 1 Water heater 1 English Manual. Parameter: Input voltage:220V Power:3KW Current:13.6A Thermostat is designed specifically for the needs of the Jacuzzi, the thermostat installed in the bottom of the tub on the massage tub, after adding hot water in the bath, start the water pump, the thermostat automatically heating insulation, the bath water temperature maintained at 30-40 adjustable, it can give your massage bathtub to create a comfortable environment. Thermostat equipped with ultra-high temperature protection thermostat switch, thermostat to limit overheating and protect users against danger, however, users should be done after the installation is complete, the first under the premise of safety checks to ensure that the operation of the thermostat’s normal function, by using the tub filled with water to a suitable level and start the system automatically checks and let the system run until the thermostat temperature stabilized at the highest level and display lights go out, use an accurate thermometer to measure the water temperature should be at 40°C. The thermostat can be maintained within a temperature not exceeding 40 °C (104 °F) range. If cold water is started, will be 6 8 °C / h elevated temperatures Input voltage:220V. Power:3KW Automatic heating: thermostat will first reach the preset temperature, then stop working until the temperature dropped a few degrees, the thermostat automatically turns on 5. Ultra-high temperature (over 49 °C), ultra-high temperature switch will automatically trip (power off) Package Include: 1 x Water Heating Thermostat 2 x Interface 1 x Manual. Info usually update later than actual status. And it won’t be updated during weekend/holidays, pls contact with us if you need any further info. Your name, Item ID, relate pictures and reason for return should be included in the message. Please repack the item carefully. The item “11KW ELECTRIC Water Heater Swimming Pool SPA Hot Tub Thermostat 220V” is in sale since Saturday, October 17, 2020. This item is in the category “Home & Garden\Yard, Garden & Outdoor Living\Pools & Spas\Pool Equipment & Parts\Pool Heaters & Solar Panels”. The seller is “bingobuy” and is located in City of Industry. This item can be shipped to United States.

  • Brand: Unbranded
  • Type: Thermostat
  • Voltage: 220 V
  • MPN: Does not apply
  • Suitable For: Hot Tubs
Share and Enjoy:
  • Digg
  • Sphinn
  • del.icio.us
  • Facebook
  • Mixx
  • Google
  • E-mail this story to a friend!
  • Furl
  • LinkedIn
  • Live
  • MySpace
  • Print this article!
  • Propeller
  • Reddit
  • description
  • Slashdot
  • Spurl
  • StumbleUpon
  • Technorati
  • TwitThis
  • YahooMyWeb

Comments are closed.